首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Determination of dexamethasone in feed by TLC and HPLC
Authors:Huetos O  Ramos M  Martín de Pozuelo M  San Andrés M  Reuvers T B
Institution:Centro Nacional de Alimentación, Instituto de Salud Carlos III, Majadahonda, Madrid, Spain.
Abstract:Two detection methods are described for the determination of dexamethasone in feed, which may be used as screening and confirmatory methods. The procedures were developed after studying different extraction and clean-up procedures: feed extraction was optimized using methylene chloride and hexane followed by a tandem solid-phase clean-up step with silica and C18 cartridges. The confirmatory method presented is based on normal-phase high-performance liquid chromatography on a Diol 5 microns column, with hexane-propan-2-ol (90:10 v/v) as mobile phase, followed by diode array detection and confirmation. All parameters are discussed, especially the extraction and clean-up steps. Recovery studies after application of the proposed method to different kinds of feed samples spiked with dexamethasone at levels between 120 and 1600 ng g-1 yielded a mean value of 55.4% with an overall standard deviation of 15.6%. The proposed procedure allows the determination of dexamethasone in feed at levels lower than 50 ng g-1.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号