首页 | 本学科首页   官方微博 | 高级检索  
     


Electrochemical aptasensor for the cancer biomarker CEA based on aptamer induced current due to formation of molybdophosphate
Authors:Zhongzhou?Si,Bin?Xie,Zhihao?Chen,Chen?Tang,Ting?Li  author-information"  >  author-information__contact u-icon-before"  >  mailto:liting@.com"   title="  liting@.com"   itemprop="  email"   data-track="  click"   data-track-action="  Email author"   data-track-label="  "  >Email author,Minghui?Yang  author-information"  >  author-information__contact u-icon-before"  >  mailto:yangminghui@csu.edu.cn"   title="  yangminghui@csu.edu.cn"   itemprop="  email"   data-track="  click"   data-track-action="  Email author"   data-track-label="  "  >Email author
Affiliation:1.Department of General Surgery, The Second Xiang-ya Hospital,Central South University,Changsha,China;2.College of Chemistry and Chemical Engineering,Central South University,Changsha,China
Abstract:The authors describe a method for signal amplification in electrochemical aptasensors. It is based on the induction of an increased electrochemical current by the aptamer captured on a glassy carbon electrode (GCE). The phosphate groups on the aptamer backbone are brought to reaction with added molybdate to form a redox-active molybdophosphate precipitate on the surface of the GCE that generates a strong electrochemical current. To further enhance sensitivity, gold nanorods (GNRs) were selected as a support for the immobilization of aptamers. The aptasensor was applied to the determination of the cancer biomarker carcinoembryonic antigen (CEA) in a sandwich format. Antibody against CEA, CEA (antigen) and GNRs modified with CEA aptamer  were sequentially captured on the GCE. The resulting aptasensor, best operated at a voltage as low as 0.18 V vs. Ag/AgCl, is highly sensitive and has a wide linear range that extends from 0.1 pg·mL?1 to 10 ng·mL?1 of CEA. This amplification strategy uses an aptamer as both the recognition probe and signal probe and therefore simplifies signal transduction. Conceivably, this detection scheme may be adapted to numerous other electrochemical bioassays if respective antibodies and aptamers are available.
Graphical abstract Schematic presentation of an electrochemical aptasensor based on aptamer induced electrochemical current for the detection of cancer biomarker carcinoembryonic antigen (CEA). Gold nanorods (GNR) are chosen for the immobilization of aptamers to increase the loading of aptamers.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏