首页 | 本学科首页   官方微博 | 高级检索  
     


Adsorptive stripping voltammetric measurements of trace amounts of platinum(II) and ruthenium(III) in the presence of 1-(2-pyridylazo)-2-naphthol
Authors:M. S. El-Shahawi   A. Z. Abu Zuhri  M. M. Kamal
Affiliation:(1) Department of Chemistry, Faculty of Science, UAE University, P.O. Box 17551, Al-Ain, United Arab Emirates;(2) Department of Chemistry, Faculty of Science, Assiut University, Assiut, Egypt
Abstract:An extremely sensitive stripping voltammetric procedure for low level measurements of platinum (II, IV) or ruthenium (III, IV) is reported. The method is based on the interfacial accumulation of the platinum (II) or ruthenium (III)-1-(2-pyridylazo)-2-naphthol complex on the surface of a hanging mercury drop electrode, followed by the reduction of the adsorbed complex during the cathodic scan. The peak potential was found to be –0.8 V vs. Ag/AgCl electrode and the reduction current of the adsorbed complex ions of platinum (II) or ruthenium (III) was measured by differential pulse cathodic stripping voltammetry. The optimum experimental conditions were: 1.5×10–7 mol/l of 1-(2-pyridylazo)-2-naphthol solution of pH 9.3, preconcentration potential of –0.2 V, accumulation time of 3 min and pulse amplitude of 50 mV with 4 mV s–1 scan rate in the presence of ethanol-water (30% v/v) — sodium sulphate (0.5 mol/l). Linear response up to 6.4 × 10–8 and 5.1 × 10–8 mol/l and a relative standard deviation (at 1.2×10–8 mol/l) of 2.4 and 1.6% (n=5) for platinum (II) and ruthenium (III) respectively were obtained. The detection limits of platinum and ruthenium were 3.2×10–10 and 4.1×10–10 mol/l, respectively. The electronic spectra of the Pt(II) — PAN and Ru(III) — PAN complexes were measured at pH 9.3 and the stoichiometric ratios of the complexes formed were obtained by the molar ratio method. The effects of some interfering ions on the proposed procedure were critically investigated. The method was found suitable for the sub-microdetermination of ruthenium (IV) and platinum (IV) after their reduction to ruthenium (III) and platinum (II) with sulphur dioxide in acid media. The applicability of the method for the analysis of binary mixtures of ruthenium (III) and (IV) or platinum (II) and (IV) has also been carried out successfully. The method is simple, rapid, precise, and promising for the determination of the tested metal ions at micro-molar concentration level.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号