Determination of 2-mercaptopropionylglycine in plasma and urine by high-performance liquid chromatography
Authors:B K?gedal  M Carlsson  T Denneberg
Abstract:Methods for quantitative analysis of total and non-protein-bound 2-mercaptopropionylglycine (2-MPG) in plasma, and total 2-MPG in urine, have been developed. By reduction of urine, plasma or deproteinized plasma samples with tributylphosphine, 2-MPG is liberated from its disulphides, and after clean-up of the sample, 2-MPG is derivatized with N-(7-dimethylamino-4-methyl-3-coumarinyl)maleimide (DACM). The 2-MPG-DACM derivative is then quantified by high-performance liquid chromatography (HPLC) with fluorimetric detection. Both ion-suppression and ion-pair HPLC gave satisfactory chromatograms. The precision of the methods was satisfactory (coefficient of variation 3.1-5.8%), analytical recovery was quantitative (85-99%) and the two HPLC techniques were well correlated (r = 0.99). Five healthy subjects receiving 500 mg of 2-MPG showed maximal total plasma concentration of 13.8-26.9 mumol/l at 3-5 h after intake, and their non-protein-bound 2-MPG was, at the same time, 62-77% of the total 2-MPG. The urinary excretion was 27.8 +/- 3.8% (mean +/- S.D.) of the given dose, most of it excreted within 12 h after intake.