首页 | 本学科首页   官方微博 | 高级检索  
     


Trace analysis of vinclozoline by gas chromatography with electrolytic conductivity detection and solid-phase extraction
Authors:P. Just   U. Greulach   G. Henze  D. Rinne
Affiliation:(1) Fachbereich Chemie, Universität Kaiserslautern, Postfach 3825, D-54286 Trier, Germany;(2) Abteilung für Anorganische und Analytische Chemie, Universität Trier, Postfach 3825, D-54286 Trier, Germany;(3) Landesamt für Wasserwirtschaft Rheinland-Pfalz, Am Zollhafen 9, D-55116 Mainz, Germany
Abstract:A procedure for the analysis of vinclozoline in tap and surface water by GC and Hall detector has been developed. Each step — the analysis of vinclozoline in acetone standard solution, in deionized water and in tap water after solid-phase extraction — was checked by statistical tests (variance homogeneity, linearity test, residue analysis, runaway tests, F-test, t-test). The detection limits and determination limits were calculated from the calibration curve and its prediction interval (according to the DFG). The detection limit for vinclozoline in tap water was found to be 0.03 mgrg/l and the determination limit is 0.06 mgrg/l by a recovery rate of 89%.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号