Chemiluminescent determination of the pesticide bromoxynil by on-line photodegradation in a flow-injection system. |
| |
Authors: | Z Pawlicová J R Albert-García I Sahuquillo Mateo J V García M Catalá Icardo J Martínez Calatayud |
| |
Institution: | Department of Analytical Chemistry, University of Valencia, Valencia, Spain. |
| |
Abstract: | A new, robust and simple method is proposed for the chemiluminescent determination of the pesticide Bromoxynil. The empirical procedure is performed with the aid of a flow-injection manifold provided with an on-line photo-reactor to obtain chemiluminescent photofragments. After a period of 12 s of irradiation with an 8 W low-pressure mercury lamp, a chemiluminescent oxidation was performed with the system potassium permanganate in a polyphosphoric acid medium. The photolysis required a basic medium (KOH 0.014 mol l(-1)) with ethanol (1%) as a sensitizer. The method allowed the determination of 134 samples (h-1) of Bromoxynil in a wide interval of concentrations, over the range 5 x 10(-3) - 1 mg l(-1); the detection limit was 5 x 10(-3) mg l(-1). The RSD (n=24) at 0.25 mg l(-1) of the pesticide level was 2.3%. The method was applied to a water sample and to a formulation. |
| |
Keywords: | |
|
|