首页 | 本学科首页   官方微博 | 高级检索  
     


Forced convection boiling heat transfer of freon-11 in a vertical annular passage
Affiliation:1. Department of Industrial Engineering, Università di Salerno, Via Giovanni Paolo II, 132, Fisciano, 84084 Salerno, Italy;2. Department of Mechanical Engineering and Construction, University Jaume I, Campus de Riu Sec s/n E-12071, Castellon de la Plana, Spain;1. Graduate School of Science and Engineering, Saga University, Saga, 840-8502, Japan;2. Department of Mechanical Engineering, Khulna University of Engineering & Technology, Khulna, 9203, Bangladesh;3. Department of Mechanical Engineering, Saga University, Saga, 840-8502, Japan;4. International Institute for Carbon-Neutral Energy Research, Kyushu University, Fukuoka, 819-0385, Japan
Abstract:Forced convection boiling heat transfer coefficient of Freon-11 flowing upward through a vertical annular passage was measured. Heating element was a single inconel heating rod placed in the center of a stainless steel pipe. The range of temperature difference between the rod surface and the saturation temperature of the Freon was 2.2–14.5°C (3.9–26.1°F), and the range of the experimental heat transfer coefficient measured was 949–3419 watt/m2-°C (167.1–602 Btu/hr-ft2-°F). The measured heat transfer coefficients agreed very well with the values computed by using Chen's correlation equation for heat transfer, and the average standard deviation between these two values was ±4.03%.
Keywords:
本文献已被 ScienceDirect 等数据库收录!