Performance of the FAST system for stress analysis |
| |
Authors: | A K Wong T G Ryall |
| |
Institution: | (1) Aeronautical and Maritime Research Laboratory, Defence Science and Technology Organisation, P.O. Box 4331, 3207 Melbourne, Victoria, Australia |
| |
Abstract: | A state-of-the-art thermographic system has been developed based on a 512×512 focal-plane array thermal imager. The system was primarily designed to perform stress analysis, but has applications in other areas where small cyclic temperature variations are encountered. A detailed analysis of its performance relative to an existing equipment (SPATE) revealed that, at least for low frequency applications, the proposed system out performs SPATE by some two to three orders of magnitude such that high-resolution area scans can now be achieved in minutes instead of hours. It is suggested that higher frequency applications (i.e., order of 102 Hz) can be achieved with more up-to-date imagers.Permission has been granted toExperimental Mechanics to publish this paper on a nonexclusive one-time basis only. This agreement is subject to the Commonwealth of Australia retaining Copyright of the paper, the author and source of the paper has been acknowledged. No meaningful changes have been made to the article without the prior consent of the author. |
| |
Keywords: | Focal-plane array thermography thermoelastic effect experimental stress analysis SPATE |
本文献已被 SpringerLink 等数据库收录! |
|