Integrating accreditation, good laboratory practice and good manufacturing practice in an industrial analytical laboratory
Authors:P. Schmidt
Affiliation:(1) ZAX Analytik, BASF Aktiengesellschaft, Carl-Bosch-Strasse 38, D-67056 Ludwigshafen, Germany Tel.: +49-621-60-45809 Fax: +49-621-60-79460 e-mail: peter.schmidt2@BASF-AG.de, DE
Abstract: The Analytical Laboratory of BASF is a central service unit for chemical analysis which can be used by all departments within the company. It carries out routine as well as non-routine work and has a high amount of R&D orders. A quality system conforming with GMP rules was installed in the 1970s, followed by a GLP system about 6 years later. In 1995 an EN 45001 certificate was granted, which also stated the conformity with ISO 9002. A "types of test" orientated system was chosen for accreditation. This was better suited to the needs of a testing laboratory with a high amount of non-routine work than a purely test-procedure orientated accreditation. An integrated quality system has now been developed from these activities. It has partly common elements and partly differing elements taking into account specific regulations. For example, instrument calibration, staff training, validation of test procedures and the use of computerized systems are covered by uniform rules. Other elements such as handling of samples and report generation are arranged according to the individual requirements of the various standards. Rules and regulations are laid down in a system of documents which comprise the quality manual, general standard operating procedures (SOPs), laboratory-specific SOPs and test procedures. The quality system has been accepted by other accreditiation bodies on application of special accreditations (workplace safety, biodegradable polymers). But it has had no advantageous influence on getting GLP certification. An integrated system is very complex and requires appreciable resources. Management of processes and documentation can only be handled by extensive use of computers. Frequent training of staff and internal audits are necessary to keep the system at an acceptable level. In order to reduce the complexity of quality management regulations a harmonization of the different quality systems would be desirable. Received: 1 October 1998 · Accepted: 10 January 1999
Keywords:  Integrated quality management system  Accreditation according to EN 45001  Good laboratory practice  Good manufacturing practice  Laboratory for chemical analyses
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号