首页 | 本学科首页   官方微博 | 高级检索  
     


Heat-transfer-based detection of l-nicotine, histamine, and serotonin using molecularly imprinted polymers as biomimetic receptors
Authors:M. Peeters  P. Csipai  B. Geerets  A. Weustenraed  B. van Grinsven  R. Thoelen  J. Gruber  W. De Ceuninck  T. J. Cleij  F. J. Troost  P. Wagner
Affiliation:1. Institute for Materials Research, Hasselt University, Wetenschapspark 1, 3590, Diepenbeek, Belgium
2. Instituto de Química, Universidade de S?o Paulo, Av. Prof. Lineu Prestes, 748, CEP 05508-000, S?o Paulo, SP, Brazil
3. Xios University College Limburg, Agoralaan—Building H, 3590, Diepenbeek, Belgium
4. Division IMOMEC, IMEC vzw, Wetenschapspark 1, 3590, Diepenbeek, Belgium
5. Division of Gastroenterology–Hepatology, Department of Internal Medicine, Maastricht University Medical Center, Minderbroedersberg 4-6, 6211 LK, Maastricht, The Netherlands
Abstract:In this work, we will present a novel approach for the detection of small molecules with molecularly imprinted polymer (MIP)-type receptors. This heat-transfer method (HTM) is based on the change in heat-transfer resistance imposed upon binding of target molecules to the MIP nanocavities. Simultaneously with that technique, the impedance is measured to validate the results. For proof-of-principle purposes, aluminum electrodes are functionalized with MIP particles, and l-nicotine measurements are performed in phosphate-buffered saline solutions. To determine if this could be extended to other templates, histamine and serotonin samples in buffer solutions are also studied. The developed sensor platform is proven to be specific for a variety of target molecules, which is in agreement with impedance spectroscopy reference tests. In addition, detection limits in the nanomolar range could be achieved, which is well within the physiologically relevant concentration regime. These limits are comparable to impedance spectroscopy, which is considered one of the state-of-the-art techniques for the analysis of small molecules with MIPs. As a first demonstration of the applicability in biological samples, measurements are performed on saliva samples spiked with l-nicotine. In summary, the combination of MIPs with HTM as a novel readout technique enables fast and low-cost measurements in buffer solutions with the possibility of extending to biological samples.
Figure
Heat-transfer based detection with molecularly imprinted polymers
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号