旋光仪维修及调整
引用本文:穆晓东,袁长坤.旋光仪维修及调整[J].大学物理实验,2013(3):36-36,43.
作者姓名:穆晓东  袁长坤
作者单位:山东理工大学,山东淄博255049
摘    要:首先提出了旋光仪在使用中出现的故障,经过分析,找出故障原因;说明维修方法以及如何调整仪器的影荫角和零位;使故障仪器不仅迅速恢复使用,而且处于最佳工作状态,同时节省了仪器厂家人员维修仪器的时间和费用。

关 键 词:旋光仪  起偏器  检偏器  半波片

Reparation and Adjustment of Polarimeter
MU Xiao-dong,YUAN Chang-kun.Reparation and Adjustment of Polarimeter[J].Physical Experiment of College,2013(3):36-36,43.
Authors:MU Xiao-dong  YUAN Chang-kun
Institution:(Shandong University of Technology, Shandong Zibo 255049)
Abstract:The faults of the polarimeter appearing in use firstly put forward in the paper. Based on analysis,the faults are found out. Ways of repairing the polarimeter and adjusting the Yingyin angle and zero position are finally explained. As a result,the polarimeter out of order is quickly returned to normal working condition. In this way,the manufacturer's repairing time and money are saved.
Keywords:polarimeter  polarizer  analyzer  half-wave plate