Comparison between filtrations at fixed transmembrane pressure and fixed permeate flux: application to a membrane bioreactor used for wastewater treatment
Institution:1. School of Civil, Environmental & Architectural Engineering, Korea University, 1-5 Ga, Anam-Dong, Sungbuk-Gu, Seoul 136-713, Republic of Korea;2. Water Technology Development Team, Corporate R&D Institute, Doosan Heavy Industries & Construction, DoosanVolvo-ro, Seongsan-gu, Changwon, Gyeongnam-Republic of Korea
Abstract:Membrane bioreactors for wastewater treatment must operate for long periods without chemical cleaning. This paper investigates the critical flux concept introduced by Field et al. as a means for achieving this goal. Experiments were conducted on a membrane bioreactor containing 600 l of activated sludge, equipped with a 0.25 m2 ceramic membrane and located in Compiegne wastewater treatment plant. Hydraulic retention time was set at 24 h and sludge retention time at 60 days, so that suspended solids concentration stabilises at 10 g/l. We conducted two series of tests: at fixed transmembrane pressure (TMP) and at fixed permeate flux, set by a volumetric pump on the permeate. In both cases, velocity was varied from 1 to 5 m/s. In fixed flux tests, the flux was increased by 10 l/h m2 increments and the TMP was observed to rise moderately first and then stabilise in about 15 min until a critical value of the flux is reached. Above this critical flux, the TMP rises rapidly and does not stabilise, as in dead-end filtration. The critical flux was found to increase approximately linearly with velocity, reaching about 115 l/h m2 at 4 m/s. These data were reproducible at various dates between 30 and 120 days of continuous operation of the bioreactor and permit to know at which flux a membrane bioreactor must be operated. Comparison of constant pressure and constant flux tests under same conditions showed that the critical flux is almost identical to the limiting or pressure independent flux obtained in constant pressure. More generally, constant flux procedure below the critical flux avoids overfouling of the membrane in the initial stage and is more advantageous for membrane bioreactor operation.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号