首页 | 本学科首页   官方微博 | 高级检索  
     

Determination of Copper by Flame Atomic Absorption Spectrometry after Preconcentration with Activated Carbon Impregnated with a New Schiff Base
引用本文:SABER TEHRANI Mohammad,RASTEGAR Faramarz,PARCHEHBAF Ayob,REZVANI Zolfaghar. Determination of Copper by Flame Atomic Absorption Spectrometry after Preconcentration with Activated Carbon Impregnated with a New Schiff Base[J]. 中国化学, 2005, 23(10): 1437-1442. DOI: 10.1002/cjoc.200591437
作者姓名:SABER TEHRANI Mohammad  RASTEGAR Faramarz  PARCHEHBAF Ayob  REZVANI Zolfaghar
作者单位:[1]Department of Chemistry, Faculty of Science, Science and Research Campus, lslamic Azad University, Tehran, Iran [2]Plate-Form Analitique lnorganique, Lois Pasteur University, Strasburg, France [3]Department of Chemistry, Faculty of Science, Azarbaijan Tarbiat Moallem University, Tabriz, Iran
摘    要:A simple and reliable method for the extraction and determination of trace amounts of copper(Ⅱ) ions using activated carbon (AC) impregnated by a new Schiff base 5-[(4-heptyloxyphenyl)azo]-N-(4-propyloxyphenyl)-salicylaldimine (HPPS) and atomic absorption spectrometry is presented. Recovery efficiency and the influence of pH value, volume of sample solution, effect of different eluents, and interfering ions were evaluated. The limit of detection (3σ) was 2.62 ng.mL^-1 and the relative standard deviation (n=10) was 1.5%. Under optimum conditions, the copper ions were concentrated 25 fold using 250 mL of sample solution and 10 mL of eluent. This procedure has been successfully applied to the determination of copper in different water samples.

关 键 词:铜 原子 吸收能力 光谱测定法 活性碳
收稿时间:2004-11-16
修稿时间:2004-11-162005-05-08

Determination of Copper by Flame Atomic Absorption Spectrometry after Preconcentration with Activated Carbon Impregnated with a New Schiff Base
SABER;TEHRANI,;Mohammad;RASTEGAR,;Faramarz;PARCHEHBAF,;Ayob;REZVANI,;Zolfaghar. Determination of Copper by Flame Atomic Absorption Spectrometry after Preconcentration with Activated Carbon Impregnated with a New Schiff Base[J]. Chinese Journal of Chemistry, 2005, 23(10): 1437-1442. DOI: 10.1002/cjoc.200591437
Authors:SABER  TEHRANI,  Mohammad  RASTEGAR,  Faramarz  PARCHEHBAF,  Ayob  REZVANI,  Zolfaghar
Abstract:A simple and reliable method for the extraction and determination of trace amounts of copper(II) ions using activated carbon (AC) impregnated by a new Schiff base 5‐[(4‐heptyloxyphenyl)azo]‐N‐(4‐propyloxyphenyl)‐salicyl‐aldimine (HPPS) and atomic absorption spectrometry is presented. Recovery efficiency and the influence of pH value, volume of sample solution, effect of different eluents, and interfering ions were evaluated. The limit of detection (3δ) was 2.62 ng·mL?1 and the relative standard deviation (n=10) was 1.5%. Under optimum conditions, the copper ions were concentrated 25 fold using 250 mL of sample solution and 10 mL of eluent. This procedure has been successfully applied to the determination of copper in different water samples.
Keywords:preconcentration   determination   copper   flame atomic absorption spectrometry   activated carbon
本文献已被 维普 等数据库收录!
点击此处可从《中国化学》浏览原始摘要信息
点击此处可从《中国化学》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号