首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Direct Spectroscopic Evidence of the Influence of Chamber Wall Condition on Oxide Etch Rate
Authors:Lee  Szetsen  Tien  Yu-Chung  Hsu  Chin-Fa
Institution:(1) Winbond Electronics Corporation, Fab 4, 9 Li Hsin Road, Hsinchu, 300, Taiwan
Abstract:The drift of TEOS etch rate has been observed during MERIE oxide etch for the damascene process. The etch rate typically fluctuates between 5300 Å/min and 6000 Å/min. Studies using fluorocarbon-based chemistry show a normal TEOS etch rate when the chamber wall is heavily coated with polymer deposition. On the other hand, a lower etch rate appears when the chamber has less deposition. Hysteresis behavior has been observed during the etch rate of TEOS, as well as emission intensity trends of F, CF x (x=1~3), and SiF. From the observed emission intensity variation of F, CF x , and SiF, a model is proposed to explain the impact of chamber wall polymer deposition on the etch rate of TEOS. This model includes a mechanism of etch rate enhancement by embedding oxygen in the chamber wall polymer. From the correlation between etch rate and emission intensity, it clearly shows that F is directly responsible for the etch of TEOS. Compared to F, CF x plasma chemistry has a closer link to chamber wall polymer formation, but contributes less in the etch of TEOS.
Keywords:Oxide  etch  polymer  deposition  emission  plasma  hysteresis  fluorocarbon  Le Chatelier's principle
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏