Direct injection of plasma to determine pseudoephedrine by high performance liquid chromatography with column switching
Authors:Guo P  Li Z  Li T  Wang X  Li F
Affiliation:Faculty of Pharmacy, West China University of Medical Sciences, People's Republic of China.
Abstract:An HPLC method has been developed for the determination of pseudoephedrine in plasma using column switching. Preparation of the sample was simple in that only 1000 microL of water was added to 200 microL of plasma before injection. A 900 microL aliquot was injected onto the precolumn. Double distilled water was used to elute and remove proteins and polar components in the sample. The components retained on the precolumn were flushed forward onto the analytical column by the mobile phase (acetonitrile-0.2 mol/L ammonium sulphate, 10:90 v/v) with automated column switching. The limit of determination of pseudoephedrine in plasma was 12 ng/mL. The relative standard deviations of intra- and inter-assay for the determination of pseudoephedrine in plasma were 1.2-9.8% over the concentration range 1020-21.8 ng/mL. The mean recovery by on-line solid phase extraction was 94.76% (RSD = 1.1%).