首页 | 本学科首页   官方微博 | 高级检索  
     

PEAK IDENTIFICATION FROM INTERACTION INDEX IN REVERSED-PHASE HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY
引用本文:陈农,张玉奎,卢佩章. PEAK IDENTIFICATION FROM INTERACTION INDEX IN REVERSED-PHASE HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY[J]. 中国科学B辑(英文版), 1992, 0(12)
作者姓名:陈农  张玉奎  卢佩章
作者单位:National Chromatographic R. & A. Center,Dalian Institute of Chemical Physics,Academia Sinica,Dalian 116011,PRC,National Chromatographic R. & A. Center,Dalian Institute of Chemical Physics,Academia Sinica,Dalian 116011,PRC,National Chromatographic R. & A. Center,Dalian Institute of Chemical Physics,Academia Sinica,Dalian 116011,PRC
摘    要:The interaction index c which was derived from the fundamental retention equationlogk' =a + cC_B in reversed--phase high--performancc liquid chromatography (RP-HPLC) quan-titatively describes the difference in the interaction between solute--strong. solvent andsolute--weak solvent; it has shown to be a constant for a specific solute even when columnsystems with different C18 packings are used. The theoretical basis for peak identificationby using interaction index has been proposed, which was based on the a,c values on stan-dard C18 column by utilizing linear a-a plots on column pairs and the linear relationship be-tween parameters a and c for the structural related compounds. Through the establishmentof parameters a,c data based on the standard C18 column for a certain type of compounds,the retention of thesc compounds on various C18 columns can be predicted. Typical exam-ples have been given to verify the correctness of this method.

关 键 词:peak identification  reversed-phase high-performance liquid chromatography  interaction index c  hydrophobic index α  linear α-α plots on column pairs  linear α-c relationship  structural related compounds

PEAK IDENTIFICATION FROM INTERACTION INDEX IN REVERSED-PHASE HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY
CHEN NONG,ZHANG YU-KUI,LU PEI-ZHANG National Chromatographic R. , A. Center,Dalian Institute of Chemical Physics,Academia Sinica,Dalian ,PRC. PEAK IDENTIFICATION FROM INTERACTION INDEX IN REVERSED-PHASE HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY[J]. Science in China(Chemistry), 1992, 0(12)
Authors:CHEN NONG  ZHANG YU-KUI  LU PEI-ZHANG National Chromatographic R. & A. Center  Dalian Institute of Chemical Physics  Academia Sinica  Dalian   PRC
Affiliation:CHEN NONG,ZHANG YU-KUI,LU PEI-ZHANG National Chromatographic R. & A. Center,Dalian Institute of Chemical Physics,Academia Sinica,Dalian 116011,PRC
Abstract:The interaction index c which was derived from the fundamental retention equationlogk' =a + cC_B in reversed--phase high--performancc liquid chromatography (RP-HPLC) quan-titatively describes the difference in the interaction between solute--strong. solvent andsolute--weak solvent; it has shown to be a constant for a specific solute even when columnsystems with different C18 packings are used. The theoretical basis for peak identificationby using interaction index has been proposed, which was based on the a,c values on stan-dard C18 column by utilizing linear a-a plots on column pairs and the linear relationship be-tween parameters a and c for the structural related compounds. Through the establishmentof parameters a,c data based on the standard C18 column for a certain type of compounds,the retention of thesc compounds on various C18 columns can be predicted. Typical exam-ples have been given to verify the correctness of this method.