摘    要:本文介绍一种扫描电镜用前级惰性气体保护装置,它可用在氩气等惰性气体气氛不装卸易燃,易爆等活性极强的样品,从而实现了活性钙样品的扫描电镜观察与分析。

关 键 词:活性钙  惰性气体  保护装置  扫描电镜
收稿时间:1994/12/7 0:00:00
修稿时间:1995/1/17 0:00:00

Fore Inert Gas Protection Device in SEM
Guo Xiaoyan,Li Shitong and Hou Xurong.Fore Inert Gas Protection Device in SEM[J].Analysis and Testing Technology and Instruments,1995,1(1):17-25.
Authors:Guo Xiaoyan  Li Shitong and Hou Xurong
Institution:Analyzing and Testing Center of Materials, Shandong University of Technology, Jinan 250014;Analyzing and Testing Center of Materials, Shandong University of Technology, Jinan 250014;Analyzing and Testing Center of Materials, Shandong University of Technology, Jinan 250014
Abstract:In thes paper a fore inert gas protection device applied to SEM has ho introduced.The very active sample which is inflammable and explosive can be handied under the inertargon atmosphere,therefore,the active calcium samples can be observed and analyzed bySEM.