Determination of ecliptasaponin A in rat plasma and tissues by liquid chromatography‐tandem mass spectrometry |
| |
Authors: | Jing Zhao Erwei Liu Lifeng Han Linlin Wang Yi Zhang Tao Wang Shiming Fang Xiumei Gao |
| |
Affiliation: | 1. Tianjin State Key Laboratory of Modern Chinese Medicine, Tianjin, China;2. Tianjin Key Laboratory of TCM Chemistry and Analysis, Tianjin University of Traditional Chinese Medicine, Tianjin, PR China |
| |
Abstract: | A sensitive, rapid and specific high‐performance liquid chromatography tandem mass spectrometry method (HPLC‐MS/MS) was developed to determine ecliptasaponin A in rat plasma and tissues after oral administration. Ginsenoside Rg1 was used as the internal standard (IS). The plasma and tissues samples were prepared by liquid‐liquid extraction with ethyl acetate and separated on an Eclipse Plus C18 column (2.1 mm × 150 mm, 5 µm) at a flow rate of 0.4 mL/min using acetonitrile and water (containing 0.05% acetic acid) as the mobile phase. The tandem mass detection was carried out with eletrospray ionization in negative mode. Quantification was performed by using multiple reaction monitoring (MRM), which monitored the fragmentation of m/z 633.4→587.2 for ecliptasaponin A and m/z 859.4→637.4 for the IS. The calibration curves obtained were linear in different matrices, and the lower limit of quantification (LLOQ) achieved was 0.5 ng/mL both for rat plasma and tissues. The intra‐ and inter‐day precisions were below 15%. This method was successfully applied to pharmacokinetic study of ecliptasaponin A in rat plasma and tissues after oral administration. Copyright © 2015 John Wiley & Sons, Ltd. |
| |
Keywords: | Ecliptasaponin A pharmacokinetics LC‐MS/MS Eclipta prostrate L |
|
|