首页 | 本学科首页   官方微博 | 高级检索  
     

柱后衍生离子色谱法同时测定瓶装水中的碘酸根、亚氯酸根和溴酸根
引用本文:周益奇,王子健,许宜平,马梅. 柱后衍生离子色谱法同时测定瓶装水中的碘酸根、亚氯酸根和溴酸根[J]. 色谱, 2007, 25(3): 430-434
作者姓名:周益奇  王子健  许宜平  马梅
作者单位:State Key Laboratory of Environmental Aquatic Chemistry, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China
基金项目:北京市自然科学基金;中国科学院方向性项目
摘    要:水中的碘酸根、亚氯酸根和溴酸根是重要的消毒副产物,主要通过大体积浓缩后直接电导检测,或通过柱前或柱后化学反应将目标物转化成容易检测的物质后检测。本方法采用大体积进样柱后衍生紫外检测的分析方法,通过条件优化获得了较高的灵敏度和信噪比。利用一套自动分析系统,可以满足饮用水中痕量碘酸根、亚氯酸根、溴酸根的同时监测。碘酸根、亚氯酸根和溴酸根的检出限分别为0.5,0.4,0.1 μg/L。对于不同的加标样品,碘酸根、亚氯酸根和溴酸根的回收率分别为70.8%~98.0%,92.4%~100%和93.2%~104.1%。该方法应用于北京市场上的瓶装饮用水分析,结果显示瓶装纯净水中的碘酸根、亚氯酸根、溴酸根浓度均低于检出限,而瓶装矿泉水中碘酸根、溴酸根的最高含量分别达到9.4 μg/L和78.4 μg/L。

关 键 词:碘酸根  离子色谱  瓶装水  溴酸根  亚氯酸根  
文章编号:1000-8713(2007)03-0430-05
收稿时间:2006-11-03
修稿时间:2006-11-03

Simultaneous Determination of Iodate, Chlorite and Bromate in Bottled Drinking Water by Ion Chromatography with Post-Column Reaction and UV Detection
ZHOU Yiqi,WANG Zijian,XU Yiping,MA Mei. Simultaneous Determination of Iodate, Chlorite and Bromate in Bottled Drinking Water by Ion Chromatography with Post-Column Reaction and UV Detection[J]. Chinese journal of chromatography, 2007, 25(3): 430-434
Authors:ZHOU Yiqi  WANG Zijian  XU Yiping  MA Mei
Affiliation:State Key Laboratory of Environmental Aquatic Chemistry, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China
Abstract:Iodate, chlorite and bromate in bottled water are disinfectant by-products (DBPs) from ozonation. The established methods for simultaneous determination of iodate, chlorite and bromate are mostly based on pre- or post-column chemical reaction in which the target compound was converted to another easily detectable species. However, the procedure suffers from several time-consuming reaction steps that involve multiple chemicals, or where the reagents themselves are toxic. In the present study, a rapid, highly sensitive, precise and accurate method was established, and a post-column reaction with sodium nitrite and acid solution of potassium bromide was employed to enhance sensitivity and to reduce interferences. Under optimized conditions, the method limits for iodate, chlorite and bromate were 0.5, 0.4 microg/L and 0.1 microg/L, respectively. Percentage recoveries of iodate, chlorite and bromate varied from 70.8% to 98.0%, 92.4% to 100% and 93.2% to 104.1% respectively with different spiked water samples. The proposed method was demonstrated for detecting the concentrations of iodate, chlorite and bromate in bottled water produced from different water sources. Results showed that severe bromate contamination was present in bottled mineral water purchased from Beijing supermarket, which used spring water or ground water as the sources.
Keywords:ion chromatography(IC)  iodate  chlorite  bromate  bottled water
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《色谱》浏览原始摘要信息
点击此处可从《色谱》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号