TL glow-curve deconvolution functions for various kinetic orders and continuous trap distribution: Acceptance criteria for E and s values |
| |
Authors: | G. Kitis |
| |
Affiliation: | (1) Nuclear Physics Laboratory, Aristotle University of Thessaloniki, GR-540 06 Thessaloniki, Greece |
| |
Abstract: | The glow curve deconvolution (GCD) analysis of a composite thermoluminescence (TL) glow curve into its individual glow-peaks needs appropriate equations describing a single glow peak. In the present work, new single glow peak equations are presented, which are produced by transformation of the I(n0,E,s,T) and I(n0,E,s,b,T) single glow-peak equations into I(Im,Tm,E,T) and I(Im,Tm,E,b,T), respectively. Moreover, equations of the forms I(Im,Tm,w,b,T) are also introduced. The proposed equations have two basic advantages: (1) they use parameters, which are directly obtained from the experimental glow peaks and (2) their accuracy is equal to that of the original thermoluminescence single glow-peak equations. |
| |
Keywords: | |
本文献已被 SpringerLink 等数据库收录! |
|