首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Condensation intensity in vapour/gas mixture
Authors:M P Maric  D D Gvozdenac  M P Stakic
Institution:(1) Institute of Thermal Energy and Process Engineering, University of Novi Sad, P.O. Box 55, 21121 Novi Sad, Yugoslavia
Abstract:Quite a large quantity of waste energy is discharged into atmosphere with vapor/gas mixture. It exceeds more than 10% of the primary energy input in a plant. By developing heat exchangers resistant to the low-temperature corrosion, an efficient use of a large part of this energy can be provided. The intensity of moist air/cold water heat transfer has been experimentally determined in a semi-in-dustrial plant and given in the form of the criterion equation (diagram) with variations of inlet gas moisture, inlet gas Reynolds number, and water flow rates. This diagram enables technically reliable calculation of any heat exchanger consisting of a bundle of vertical tubes in a tube sheet.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号