首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Proton response of high sensitivity CR-39 copolymer
Authors:K Ogura  T Hattori  M Asano  M Yoshida  H Omichi  N Nagaoka  H Kubota  R Katakai  H Hasegawa
Institution:

* College of Industrial Technology, Nihon University, 1-2-1 Izumi-cho, Narashino, Chiba 275, Japan

** Department of Material Development, Takasaki Radiation Chemistry Research Establishment, Japan Atomic Energy Research Institute, 1233 Watanuki, Takasaki, Gunma 370-12, Japan

*** Department of Chemistry, Faculty of Engineering, Gunma University, 1-5-1 Tenjin, Kiryu, Gunma 376, Japan

**** Fukuvi Chemical Industry Co., Ltd., Sakai-cho, Sakaigun, Fukui 915-05, Japan

Abstract:We studied the track response for the copolymer of CR-39 monomer with N-isopropylacrylamide (NIPAAm) as well as etching properties. It was found that copoly (CR-39/NIPAAm/Naugard 445) composed in wieght ratio of 99/1/0.01 is highly sensitive to low LET particles in the region below 10 keV/μm of LETImage and able to record normally incident particles of LETImage down to not, vert, similar1.5 keV/μm, recording protons up to the energy of 27 MeV. These results were compared with the responses for two types of CR-39 detectors containing a small quantity of antioxidant. The threshold energy proton registration is discussed.
Keywords:Track detector  CR-39/NIPAAm copolymer  proton response  high sensitivity