Calibration studies and the application of nuclear track detectors to the detection of charged particles
Institution:1. P. N. Lebedev Physics Institute, Russian Academy of Sciences, 119991 Moscow, Russia;2. Physics Faculty and International Laser Center of M.V. Lomonosov Moscow State University, Moscow, 119991, Russia;3. Center for Fundamental and Applied Research, Dukhov Research Institute, ROSATOM, Moscow, 127055, Russia;4. ITMO University, 197101 St. Petersburg, Russia
Abstract:This paper describes calibration studies of solid state nuclear track detectors (SSNTDs) of he CR-39/PM-355 type. A dozen or so PM-355 detector samples were cut out from detector sheets delivered at different times and were irradiated with mono-energetic protons, deurerons and helium ions of energy ranging up to a few MeV. After that, the samples were etched and track opening diameters were determined as a function of particle energy and detector etching time. These studies were motivated by the application of the detectors in fusion experiments to measure energetic ions which escape high-temperature plasmas. The calibration diagrams obtained enable us to compare the relative sensitivities of detectors from different batches and to use these detectors in an optimal way.
Keywords:
本文献已被 ScienceDirect 等数据库收录!