Comparative validation study to demonstrate the equivalence of a minor modification to AOAC methods 996.09, Vip for EHEC and 996.10, assurance Eia EHEC with the reference culture method for the detection of Escherichia coli O157:H7 in beef |
| |
Authors: | Feldsine Philip T Green Shannon T Lienau Andrew H Kerr David E |
| |
Affiliation: | BioControl Systems, Inc., 12822 SE 32nd St, Bellevue, WA 98005, USA. ptf@biocontrolsys.com |
| |
Abstract: | The Visual Immunoprecipitate Assay (VIP) method for the detection of enterohemorrhagic Escherichia coli O157:H7 (VIP for EHEC) and Assurance Enzyme Immunoassay (EIA) method for the detection of EHEC (EHEC EIA) are AOAC INTERNATIONAL Official Methods 996.09 and 996.10, respectively. A minor modification to the enrichment medium used in both methods has been developed. This modification, the BioControl modified EHEC medium (BioControl mEHEC) provides a more cost-effective procedure with performance equivalent to that of the cultural method for detection of E. coli O157:H7 in beef. |
| |
Keywords: | |
本文献已被 PubMed 等数据库收录! |
|