首页 | 本学科首页   官方微博 | 高级检索  
     


Determination of nanomolar lead (II) using H2O2-oxidized activated carbon modified electrode
Authors:Jinyi Chen  Guangzhong Yang  Wanyi Li  Jiashou Sun
Affiliation:(1) College of Chemistry and Environmental Engineering, Yangtze University, Jingzhou, 434023, China
Abstract:The virgin activated carbon (AC) was oxidized by 30% H2O2 under the ultrasonic condition for 6 h (denoted as AC-6). The electrochemical response of Pb2+ at the AC-6 modified paste electrode was investigated, suggesting that AC-6 shows much higher accumulation efficiency to trace levels of Pb2+. Based on this, a sensitive and convenient electrochemical method was developed for the determination of Pb2+ utilizing the excellent properties of AC-6. In pH 3.6 HAc-NaAc buffer, Pb2+ was easily accumulate at the surface of AC-6 modified paste electrode, then reduced to Pb at −1.20 V. During the following anodic sweep, the reduced Pb was oxidized and resulted in an oxidation stripping peak at −0.58 V. The stripping peak current is proportional to the concentration of Pb2+ over the range from the 8.0 × 10−9 to 2.0 × 10−6 mol l−1, and the limit of detection is as low as 2.0 × 10−9 mol l−1. Finally, this newly-developed method was successfully employed to determine Pb2+ in water samples.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号