首页 | 本学科首页   官方微博 | 高级检索  
     

Ferron比色法中不同Ferron体系、溶解度和实验温度等因素对测定单核铝浓度的影响
引用本文:金 晶,常 方,张振江,毕树平. Ferron比色法中不同Ferron体系、溶解度和实验温度等因素对测定单核铝浓度的影响[J]. 光谱学与光谱分析, 2015, 35(9): 2457-2462. DOI: 10.3964/j.issn.1000-0593(2015)09-2457-06
作者姓名:金 晶  常 方  张振江  毕树平
作者单位:南京大学化学化工学院,江苏 南京 210093
摘    要:Ferron比色法被广泛应用于铝形态分析检测中,但迄今为止可能影响其测量准确性的某些重要因素尚未进行过系统研究。以Al-Ferron显色体系摩尔吸光系数ε值为关键,系列考察了不同Ferron体系、Ferron溶解度、实验温度、离子强度和参比体系这五个因素对Ferron比色法测定单核铝浓度准确度的影响。研究结果表明:不同Ferron体系、Ferron的溶解度、实验温度是Ferron比色法中的重要因素,测定时应当予以高度重视,否则会影响测量结果的准确性;溶液的离子强度以及参比体系等则对测定基本无影响。通过实验结果以及相关文献的总结分析,优化了Ferron比色法的测定条件,从而为获得准确的单核铝浓度测量结果所需要采取的操作程序提供了标准规范。

关 键 词:Ferron比色法  单核铝浓度  摩尔吸光系数ε值  测定条件优化  影响因素   
收稿时间:2015-04-08

Study on the Effects of Different Ferron System,Ferron Solubility,Experimental Temperature and Other Factors for the Accurate Determination of Mononuclear Aluminum Concentration in Aqueous Solution
JIN Jing,CHANG Fang,ZHANG Zhen-jiang,BI Shu-ping. Study on the Effects of Different Ferron System,Ferron Solubility,Experimental Temperature and Other Factors for the Accurate Determination of Mononuclear Aluminum Concentration in Aqueous Solution[J]. Spectroscopy and Spectral Analysis, 2015, 35(9): 2457-2462. DOI: 10.3964/j.issn.1000-0593(2015)09-2457-06
Authors:JIN Jing  CHANG Fang  ZHANG Zhen-jiang  BI Shu-ping
Affiliation:School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210093, China
Abstract:Ferron colorimetric method has been widely used in aluminum speciation analysis. However, some important factors that may affect the accurate determination of mononuclear Al concentration have not been studied yet. Using molar absorption coefficient ε as a key indicator, the critical issues in Al-Ferron coloring reaction system have been investigated experimentally in this paper, including different Ferron system, Ferron solubility, experimental temperature, ionic strength and the reference system. The results show that three vital factors (different Ferron colorimetric system, Ferron solubility and experimental temperature) would significantly affect the accurate measurement of mononuclear Al concentration; whereas, other two factors like ionic strength and the reference have litter influence. Base on our experimental results and statistic analysis of relevant important literatures, we suggest that optimizing colorimetric conditions and standardizing operational procedures should be paid much more attention in Ferron colorimetric assay in order to obtain the accurate measurement results.
Keywords:Ferron colorimetric method  Mononuclear Al concentration  Molar absorption coefficient ε  Optimum conditions  Influential factors   
本文献已被 CNKI 等数据库收录!
点击此处可从《光谱学与光谱分析》浏览原始摘要信息
点击此处可从《光谱学与光谱分析》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号