Numerical approach to new tangential slot effect on film cooling effectiveness over asymmetrical turbine blade
Authors:Z Senouci  M Benabed
Institution:1.University of Science and Technologies,Oran,Algeria
Abstract:The focus of this numerical study is to conceive a new basic film cooling configuration in order to increase film cooling effectiveness, especially at the leading edge zone between the injection holes where cooling is mostly needed. The new configuration, resulting from the tangential slot configuration and especially adapted to the leading edge of an asymmetrical blade, is compared to the uniform slot configuration. Three alternatives geometries were proposed and numerically tested to find the configuration that provides the best film cooling effectiveness. The simulation is conducted at a fixed density ratio of 1.0 and a blowing ratio of 0.7. A new parameter, Rc, is defined to measure the rate of blade coverage by the film cooling. The outcomes of the numerical results indicate that the three proposed configurations allow better thermal protection because of their higher film cooling coverage. At suction side, the new configurations provide a better film cooling coverage than the baseline case. The minimal improvement is at approximately 34%, with a light superiority of case 1. At pressure side, the use of the tangential slot is especially interesting for the allowed minimum adiabatic effectiveness values between 0.3 and 0.5.
Keywords:
本文献已被 SpringerLink 等数据库收录!