首页 | 本学科首页   官方微博 | 高级检索  
     检索      


In and ex vivo breast disease study by Raman spectroscopy
Authors:L Raniero  R A Canevari  L N Z Ramalho  F S Ramalho  E A P dos Santos  R A Bitar  K J Jalkanen  H S Martinho  A A Martin
Institution:1. Laboratory of Biomedical Vibrational Spectroscopy (LEVB), Institute of Research and Development, IP&D, Universidade do Vale do Para??ba, UniVap, Avenida Shishima Hifumi, 2911, Urbanova, S?o Jos?? dos Campos, SP, CEP 12244-000, Brazil
2. Departamento de Patologia e Medicina Legal, Faculdade de Medicina de Ribeir?o Preto, Universidade de S?o Paulo, Avenida Bandeirantes, 3900, Monte Alegre, Ribeir?o Preto, SP, CEP 14049-900, Brazil
3. Department of Physics, Quantum Protein (QuP) Center, Technical University of Denmark, 2800, Kgs. Lyngby, Denmark
4. Centro de Ci??ncias Naturais e Humanas, Universidade Federal do ABC, Rua Santa Ad??lia, 166, Bangu, Santo Andr??, SP, CEP 09210-170, Brazil
Abstract:In this work, Raman spectra in the 900?C1,800?cm?1 wavenumber region of in vivo and ex vivo breast tissues of both healthy mice (normal) and mice with induced mammary gland tumors (abnormal) were measured. In the case of the in vivo tissues, the Raman spectra were collected for both transcutaneous (with skin) and skin-removed tissues. To identify the spectral differences between normal and cancer breast tissue, the paired t-test was carried out for each wavenumber using the whole spectral range from both groups. Quadratic discriminate analysis based on principal component analysis (PCA) was also used to determine and evaluate differences in the Raman spectra for the various samples as a basis for diagnostic purposes. The differences in the Raman spectra of the samples were due to biochemical changes at the molecular, cellular and tissue levels. The sensitivity and specificity of the classification scheme based on the differences in the Raman spectra obtained by PCA were evaluated using the receiver operating characteristic (ROC) curve. The in vivo transcutaneous normal and abnormal tissues were correctly classified based on their measured Raman spectra with a discriminant proportion of 73%, while the in vivo skin-removed normal and abnormal tissues were correctly classified again based on their measured Raman spectra with a discriminant proportion of 86%. This result reveals a strong influence due to the skin of the breast, which decreased the specificity by 11%. Finally, the results from ex vivo measurements gave the highest specificity and sensitivity: 96 and 97%, respectively, as well as a largest percentage for correct discrimination: 94%. Now that the important bands have been experimentally determined in this and other works, what remains is for first principles molecular-level simulations to determine whether the changes are simply due to conformational changes, due to aggregation, due to changes in the environment, or complex interactions of all of the above.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号