The correction for the counting yield in nuclear spectroscopy |
| |
Authors: | W Görner |
| |
Institution: | 1. Rossendorf Department of Nuclear Chemistry, Academy of Sciences of the GDR, Central Institute of Nuclear Research, P.0.B. 19, 8051, Dresden, (GDR)
|
| |
Abstract: | Pulser and live timer are alternate tools. Dead time effects can be expressed in terms of a pulse rate dependent factor of the counting yield. The task of their correction should be shifted from the live timer of the ADC to a central timing unit. A new method is proposed, combining the advantages of the pulser and the live timer, where by each selected and accepted event is adjoined to a clock time interval and each selected but not accepted event to a dead time interval. The length of each interval is determined by the arrival of the next selected event. |
| |
Keywords: | |
本文献已被 SpringerLink 等数据库收录! |
|