首页 | 本学科首页   官方微博 | 高级检索  
     


Increasing Preservation Efficiency and Product Quality through Control of Temperature Distributions in High Pressure Applications
Authors:Wouter De Heij  Ludo Van Schepdael  Robert Van Den Berg  Paul Bartels
Affiliation:1. Agrotechnological Research Institute ATO , P.O. Box 17, Wageningen, 6700 AA, The Netherlands;2. Solico b.v. , Meerpaal 12a, Oosterhout, The Netherlands;3. Agrotechnological Research Institute ATO , P.O. Box 17, Wageningen, 6700 AA, The Netherlands Phone: +31 317 472530 E-mail: r.w.vandenberg@ato.wag-ur.nl
Abstract:

The effectiveness of HP sterilisation is a function of both temperature and pressure. As during pressurisation the product temperature increases, heat transfer to the colder HPP vessel wall occurs and the product fraction near the vessel wall will be colder than the product in the middle of the vessel. The effect of the temperature distribution in the vessel on the inactivation of Bacillus stearothermophilus has been examined. A mathematical model has been built, in which both thermodynamics and inactivation kinetics are integrated. Heat transfer is based on a Finite Element simulation, inactivation kinetics are based on first order kinetics. Based on this model and experiments the effect of an homogeneous temperature distribution on inactivation is demonstrated.
Keywords:High Pressure  Sterilisation  Adiabatic Temperature Rise  Homogeneous Temperature  Kinetic Model  Fem Modelling