首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Neutron activation analysis of manganese and nickel in commercial steel samples
Authors:S F Patil  N G Adhyapak  B M Pardeshi
Institution:(1) Department of Chemistry, University of Poona, 411 007 Pune, India
Abstract:The non-destructive thermal neutron activation analysis of some commercially available steel samples viz. SS-316, SS-310, SS-304, Tiscral, CA55 and EN 8 is carried out using a252Cf source. The manganese content of these steel samples is estimated by measuring the gamma-activity of56Mn using a single channel analyzer on integration mode and a NaI/Tl/ detector as well as using a high purity germanium detector coupled to a 4K multichannel analyzer. The results obtained by both procedures show reasonable agreement with each other. The nickel content of the various steel samples is also estimated.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏