首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Determination of sources of lead in tap water by inductively coupled plasma mass spectrometry (ICP-MS)
Authors:E S Hall  Eileen Murphy
Institution:(1) Department of Chemistry, Rutgers, The State University of New Jersey, 088903 New Brunswick, NJ, USA;(2) Division of Science and Research, New Jersey Department of Environmental Protection and Energy, 08625 Trenton, NJ, USA
Abstract:We measured the concentrations of Pb and its isotope ratios in coconmittantly obtained tap water and plumbing materials by inductively coupled mass spectrometry (ICP-MS). The Pb concentrations were determined by external calibration with209Bi as an internal standard. Isotope ratios were measured and mass discrimination corrected by normalization to NIST SRM-981 (common lead isotopic standard). Student/s t-test was used to compare the isotopic ratios of206Pb/207Pb,206Pb/208Pb, and207Pb/208Pb in the tap water with those in various plumbing materials. The comparisons revealed that the source of Pb in most of the tap water samples was derived from copper pipe or solder.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏