High-performance liquid chromatographic measurement of 8-methoxypsoralen in plasma |
| |
Authors: | F Susanto S Humfeld H Reinauer R Meschig |
| |
Institution: | (1) Department of Clinical Biochemistry, Diabetic Research Institute, University of Düsseldorf, Auf'm Hennekamp 65, D-4000 Düsseldorf 1, FRG;(2) Department of Dermatology, University of Düsseldorf, Moorenstr. 5, D-4000 Düsseldorf 1, FRG |
| |
Abstract: | Summary A simple high-performance liquid chromatographic method for the measurement of 8-Methoxypsoralen (8-MOP) in human plasma following
a single 40mg dose has been described. After addition of phosphate-NaOH buffer, pH 12, and internal standard (trimethylpsoralen),
the sample is vortex-mixed with diisopropylether. The resulting extract is analysed on a reverse phase column using phosphoric
acid (0.05% v/v): acetonitrile (1:1) as mobile phase, and U.V. detection at 220nm. No interference from endogenous sources
has been observed. The limit of sensitivity of the assay is 5ng/ml plasma. The measuring range is between 10–700ng 8-MOP/ml
plasma, to be expected from oral doses of 0.6mg 8-MOP/kg body weight, and corresponds to the therapeutic plasma concentration.
The relative standard deviation at 50ng/ml level of 8-MOP is 3.6%. |
| |
Keywords: | Column liquid chromatography 8-Methoxypsoralen Drug monitoring |