Method for improving the accuracy of continuous X-ray fluorescence analysis of iron ore mixtures
Authors:A I Volkov  N V Alov
Institution:1.Faculty of Chemistry,Moscow State University,Moscow,Russia
Abstract:The dependence of the intensity of X-ray fluorescence on the distance between the spectrometer and the test sample is studied. Changes in the intensity of primary X-radiation, absorption of X-rays by the air, and surface area of the analyzed material are calculated. An efficient method is proposed for improving the accuracy of continuous X-ray fluorescence analysis of iron ore mixtures on the conveyor belt through the exclusion of incorrect results by the dead time of the detection unit. The proposed method is universal and can be used for various loose materials.
Keywords:
本文献已被 SpringerLink 等数据库收录!