首页 | 本学科首页   官方微博 | 高级检索  
     


Sensitization of glycine (spectrophotometric read-out) dosimetric system using sorbitol
Authors:S.H. Shinde  T. Mukherjee
Affiliation:aRadiation Safety Systems Division, Bhabha Atomic Research Centre, Mumbai 400 085, India;bChemistry Group, Bhabha Atomic Research Centre, Mumbai 400 085, India
Abstract:Glycine spectrophotometric read-out systems have a useful dose range of 15–4000 Gy. An attempt was made to sensitize it using sorbitol as a sensitizer. Optimum compositions of aqueous acidic solutions of ferrous ammonium sulphate–xylenol orange (XO), i.e. FX and sorbitol–ferrous ammonium sulphate–xylenol orange, i.e. SFX, for 400 mg of glycine, which gives maximum dosimetric response for any given dose, were established. Molar absorption coefficient values of ferric–XO–glycine complex, i.e. var epsilon-values, were determined for glycine system in FX and SFX. These values were found to be 8410 and 15,000 m2 mol−1 respectively, indicating that an enhancement or sensitivity factor of about 1.78 can be achieved by sorbitol for glycine in SFX. This factor was further confirmed by measuring the gamma dose response of glycine in FX and in SFX for four different doses, viz. 37.8, 75.5, 151 and 302 Gy. It was observed that dose response of glycine in SFX is about 77% more than that of glycine in FX. The maximum variation observed in response of glycine in FX or SFX was found to be within ±1.5%.
Keywords:Glycine system   Spectrophotometric read-out method   Sorbitol sensitizer
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏