首页 | 本学科首页   官方微博 | 高级检索  
     

MIL-53(Fe)@聚多巴胺@Fe_3O_4磁性复合材料的制备及其用于环境水样中磺酰脲类除草剂的磁固相萃取
引用本文:邓玉兰,李傲天,王燕飞,孙鹏,苏萍,杨屹. MIL-53(Fe)@聚多巴胺@Fe_3O_4磁性复合材料的制备及其用于环境水样中磺酰脲类除草剂的磁固相萃取[J]. 色谱, 2018, 36(3): 253-260. DOI: 10.3724/SP.J.1123.2017.11041
作者姓名:邓玉兰  李傲天  王燕飞  孙鹏  苏萍  杨屹
作者单位:1. 北京化工大学理学院, 北京 100029;2. 中国检验检疫科学研究院, 北京 100123
基金项目:国家重点研发计划(2016YFF0204303);国家自然科学基金(21675008).
摘    要:制备了MIL-53(Fe)和聚多巴胺(PDA)修饰的磁性Fe_3O_4复合材料MIL-53(Fe)@PDA@Fe_3O_4,并将其作为吸附剂用于磁固相萃取-高效液相色谱法(MSPE-HPLC)检测环境水样中4种磺酰脲类除草剂(甲嘧磺隆、苄嘧磺隆、吡嘧磺隆和氯嘧磺隆)。实验优化了高效液相色谱条件(乙腈和含0.01%(体积分数)三氟乙酸的水溶液为流动相进行梯度洗脱,检测波长为233 nm)及磁固相萃取条件(洗脱剂为5 mL丙酮,萃取时间为4.5 min,吸附剂用量为60 mg,NaCl加入量为0.5 g,溶液pH值为3),在最佳条件下进行方法学考察,4种磺酰脲类除草剂均得到良好的线性关系,相关系数(r)≥0.998 0。方法的检出限(LOD,S/N=3)为0.28~0.77μg/L。将建立的方法用于3种环境水样中4种磺酰脲类除草剂的检测,其加标回收率为78.8%~109.7%。结果表明,制备的功能化复合材料结合了MIL-53(Fe)和Fe_3O_4的优点,可以简便快速地萃取分离环境水样中磺酰脲类除草剂。

关 键 词:磁固相萃取  高效液相色谱  金属-有机骨架  聚多巴胺  磺酰脲类除草剂  环境水样
收稿时间:2017-11-23

Preparation of MIL-53(Fe)@polydopamine@Fe3O4 magnetic composite for magnetic solid-phase extraction of sulfonylurea herbicides in environmental water
DENG Yulan,LI Aotian,WANG Yanfei,SUN Peng,SU Ping,YANG Yi. Preparation of MIL-53(Fe)@polydopamine@Fe3O4 magnetic composite for magnetic solid-phase extraction of sulfonylurea herbicides in environmental water[J]. Chinese journal of chromatography, 2018, 36(3): 253-260. DOI: 10.3724/SP.J.1123.2017.11041
Authors:DENG Yulan  LI Aotian  WANG Yanfei  SUN Peng  SU Ping  YANG Yi
Affiliation:1. College of Science, Beijing University of Chemical Technology, Beijing 100029, China;2. Chinese Academy of Inspection and Quarantine, Beijing 100123, China
Abstract:Polydopamine (PDA) and MIL-53(Fe) modified Fe3O4 particles (MIL-53(Fe)@PDA@Fe3O4 magnetic composite) were prepared by simple one-pot solvothermal method. The obtained composite was introduced to rapidly extract four kinds of sulfonylurea herbicides (SUHs) from environmental water samples by magnetic solid-phase extraction (MSPE). Then the herbicides were analyzed by a high performance liquid chromatographic system equipped with a photodiode array detector. The mobile phase was a mixture of acetonitrile and water containing 0.01% (v/v) trifluoroacetic acid, and the detection wavelength was 233 nm. Significant extraction parameters were optimized to improve the extraction efficiency. Under the optimum conditions (5 mL desorption solvent of acetone, 4.5 min extraction time, 60 mg adsorbent dosage, 0.5 g NaCl and the pH 3 of the solution), the developed method showed good linearities with correlation coefficients (r) no less than 0.9980. The limits of detection (LODs, S/N=3) of the four SUHs were 0.28-0.77 μg/L. The method was successfully used to determine four SUHs in three kinds of environmental water samples with satisfactory recoveries ranging from 78.8% to 109.7%. Therefore, the MIL-53(Fe)@PDA@Fe3O4 magnetic composite is efficient and has good potential for the extraction of SUHs.
Keywords:magnetic solid-phase extraction (MSPE)  high performance liquid chromatography (HPLC)  metal-organic frameworks (MOFs)  polydopamine (PDA)  sulfonylurea herbicides (SUHs)  environmental water sample
本文献已被 CNKI 等数据库收录!
点击此处可从《色谱》浏览原始摘要信息
点击此处可从《色谱》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号