首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Measuring gauge-mediated supersymmetry breaking parameters at a 500 GeV e^+e^- linear collider
Authors:S Ambrosanio  GA Blair
Institution:(1) CERN – Theory Division, 1211 Geneva 23, Switzerland (ambros@mail.cern.ch), CH;(2) Royal Holloway and Bedford New College, University of London, Egham Hill, Egham, Surrey TW20 0EX, UK (g.blair@rhbnc.ac.uk), GB;(3) Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, 22603 Hamburg, Germany, DE
Abstract:We consider the phenomenology of a class of gauge-mediated supersymmetry (SUSY) breaking (GMSB) models at a Linear Collider (LC) with up to 500 GeV. In particular, we refer to a high-luminosity ( cm s) machine, and use detailed simulation tools for a proposed detector. Among the GMSB-model building options, we define a simple framework and outline its predictions at the LC, under the assumption that no SUSY signal is detected at LEP or Tevatron. We assess the potential of the LC to distinguish between the various SUSY model options and to measure the underlying parameters with high precision, including for those scenarios where a clear SUSY signal would have already been detected at the LHC before starting the LC operations. Our focus is on the case where a neutralino () is the next-to-lightest SUSY particle (NLSP), for which we determine the relevant regions of the GMSB parameter space. Many observables are calculated and discussed, including production cross sections, NLSP decay widths, branching ratios and distributions, for dominant and rare channels. We sketch how to extract the messenger and electroweak scale model parameters from a spectrum measured via, e.g. threshold-scanning techniques. Several experimental methods to measure the NLSP mass and lifetime are proposed and simulated in detail. We show that these methods can cover most of the lifetime range allowed by perturbativity requirements and suggested by cosmology in GMSB models. Also, they are relevant for any general low-energy SUSY breaking scenario. Values of as short as 10's of m and as long as 10's of m can be measured with errors at the level of 10% or better after one year of LC running with high luminosity. We discuss how to determine a narrow range () for the fundamental SUSY breaking scale , based on the measured , . Finally, we suggest how to optimise the LC detector performance for this purpose. Received: 19 May 1999 / Published online: 8 December 1999
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号