首页 | 本学科首页   官方微博 | 高级检索  
     


Rapid dissolution procedure for base-metals-bearing complex materials for quality control assessment
Authors:Partha Chattopadhyay  Sukanta Mishra
Affiliation:(1) Regional Research Laboratory (Council of Scientific and Industrial Research), Bhubaneswar 751013, Orissa, India
Abstract:A less labour-intensive method, involving a mixture of 1.0 g MnO2 + 20 mL HCl (1ratio1), is proposed for decomposing seven ores and six metallurgical products for accurate and precise estimation of copper, lead, zinc, cobalt and nickel for quality control assessment. Twentyone international reference materials were also analysed. Results of regression analyses are presented and intermethod comparison studies reveal that the probability of results being different compared with a reference method was less than 1%. Sample decomposition is straightforward and the method has been found to be very simple, rapid and easily adaptable, as it involves no separation of the analyte from the matrix elements.
Keywords:Cu  Pb  Zn  Co  Ni  FAAS  complex materials  sample dissolution  quality control assessment
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号