首页 | 本学科首页   官方微博 | 高级检索  
     


Gamma-Ray and Neutron Dosimetry Using Semiconductor Silicon Diodes
Authors:A. M. Eid  M. A. Gomaa
Abstract:Radiation response to gamma-ray absorbed dose in the range of 10 to 750 kGy and neutron absorbed dose in the range of 10 mGy to 700 Gy were investigated using Swedish manufactured silicon diode, type 5422. The results indicated that its sensitivity to gamma-rays is 17.6 m V/kGY up to 60 kGy, and its sensitivity reduces to 10-17 mV/kGy from 70 kGy up to 700 kGy within an error of ±7%, while its response to fast fission neutrons is G7 mV/Gy. Factors affecting dosimeter reading such as dosimeter reading at high temperature, dosimeter annealing and reusability are also studied. The system teas used for gamma-ray and neutron dosimetry around high level gamma-ray source, reactor ducted concrete shield, and it is also examined for reactor core dosimetry.
Keywords:dosemeters  dosimetry  fast neutrons  gamma radiation  semiconductor detectors  silicon diodes
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号