首页 | 本学科首页   官方微博 | 高级检索  
     检索      

基于大气氧光谱吸收特性的单目单波段被动测距
引用本文:安永泉,李晋华,王志斌,王召巴.基于大气氧光谱吸收特性的单目单波段被动测距[J].物理学报,2013,62(14):144210-144210.
作者姓名:安永泉  李晋华  王志斌  王召巴
作者单位:1. 中北大学, 山西省光电信息与仪器工程技术研究中心, 太原 030051;2. 中北大学, 仪器科学与动态测试教育部重点实验室, 太原 030051;3. 中北大学, 电子测试技术重点实验室, 太原 030051
基金项目:国家自然科学基金仪器专项基金,国家自然科学基金,国际科技合作项目(批准号:2012DFA10680)资助的课题.*Project supported by the Special Fund for Instrument of Natural Science Foundation of China,the National Natural Science Foundation of China,the Cooperation Project of International Science and Technology
摘    要:根据目标红外辐射在大气中传输衰减的特性探测传感器与目标的距离, 隐身无源, 难于被敌方探测, 发展了一种基于大气氧组分光谱吸收特性的单目单波段被动测距方法.引入视线路径的概念, 将氧物性分布场离散化, 寻找辐射积分路径; 利用离散传递法基本思想, 得到目标窄带辐射强度分布.基于氧分子吸收发射谱独立、吸收系数恰当, 饱和可测范围大等特性, 分析氧吸收波段内谐振频带和远谐振频带辐射强度谱线分布的相对关系, 得到其与积分路径(即距离)的关联. 采用分辨率为0.75 nm半高宽的窄带高分辨率光谱仪, 实地校准氧物性分布场, 实现了测距实验范围75–200 m, 模型测算相对误差最大为7.56%的样机. 关键词: 被动测距 单目测距 单波段测距 氧光谱

关 键 词:被动测距  单目测距  单波段测距  氧光谱
收稿时间:2012-12-14

Mono-station and single-band passive ranging based on oxygen spectrum
An Yong-Quan , Li Jin-Hua , Wang Zhi-Bin , Wang Zhao-Ba.Mono-station and single-band passive ranging based on oxygen spectrum[J].Acta Physica Sinica,2013,62(14):144210-144210.
Authors:An Yong-Quan  Li Jin-Hua  Wang Zhi-Bin  Wang Zhao-Ba
Abstract:Passive ranging has received much attention because of its concealment. The distance between sensor and the object is measured by the infrared radiation attenuation in atmosphere. A mono-station single-band ranging method based on spectra transmission characteristics of oxygen is developed. The concept of light of sight (LOS) is introduced. The ray tracing model is built. With the method of discrete transfer and the discretization of physical properties distribution field of oxygen, the radiation strength in oxygen band of the target is calculated by the LOS along the seeker detectors. The radiation strengths in resonant frequency band and non-resonant frequency band are analyzed. The distance is achieved by their relation. High-resolution spectrometer is adopted to build experiment platform. Real-time dynamic ranging can be implemented by field calibration. The present experimental range is 75-200 m. The maximal relative error is 7.56%.
Keywords: passive ranging mono-station ranging single-band ranging oxygen absorption spectrum
Keywords:passive ranging  mono-station ranging  single-band ranging  oxygen absorption spectrum
本文献已被 万方数据 等数据库收录!
点击此处可从《物理学报》浏览原始摘要信息
点击此处可从《物理学报》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号