Liquid membrane-electrodes XIV |
| |
Authors: | Elena Hopîrtean M Preda and C Liteanu |
| |
Institution: | (1) Department of Analytical Chemistry, University of Cluj-Napoca, Cluj-Napoca, Romania;(2) Department of Chemistry, University of Craiova, Craiova, Romania |
| |
Abstract: | Summary FeCl
4
–
-selective liquid membrane-electrodes were prepared by using triphenylpyrilium, phenylbenzopyrilium and cetylpyridinium tetrachloroferrates and dichloroethane or tetrachloroethane as solvents. With regard to selectivity, sensitivity and concentration range the triphenylpyrilium electrode in dichloroethane proved to be most advantageous. Its response is practically Nernstian in the concentration range of 10–1 to 10–4 M FeCl
4
–
, ZnCl2, CuCl2, MnCl2, NiCl2, CdCl2, AlCl3, NO
3
–
and Br– do not cause any interference.
Flüssigmembran-Elektroden XIVUntersuchung einer Tetrachloroferrat-selektiven Flüssigmembran-Elektrode Zusammenfassung FeCl
4
–
-selektive Flüssigmembran-Elektroden wurden unter Verwendung von Triphenylpyrilium-, Phenylbenzo-pyrilium- und Cetylpyridinium-tetrachloroferraten in Dichloräthan oder Tetrachloräthan als Lösungsmittel hergestellt. In bezug auf Empfindlichkeit, Selektivität und Konzentrationsbereich erwies sich die Triphenyl-pyriliumelektrode in Dichloräthan als am vorteilhaftesten. Im Bereich von 10–1 bis 10–4 FeCl
4
–
verhält sich diese Elektrode praktisch gemäß dem Nernstschen Gesetz. ZnCl2, CuCl(in2), MnCl2, NiCl2, CdCl2, AlCl3, NO
3
–
und Br– stören nicht. Part XIII: Chem. Anal. (Warsaw) 21, 867 (1976). |
| |
Keywords: | Best von Eisen Elektroden ionenselektive Triphenylpyrilium-FeCl
4
– Dichlorä than |
本文献已被 SpringerLink 等数据库收录! |
|