首页 | 本学科首页   官方微博 | 高级检索  
     


Direct determination of non-steroidal anti-inflammatory drugs by column-switching LC-MS
Authors:Suenami Koichi  Wah Lim Lee  Takeuchi Toyohide  Sasajima Yasuhide  Sato Kiyohito  Takekoshi Yuji  Kanno Susumu
Affiliation:Department of Chemistry, Faculty of Engineering, Gifu University, Gifu, Japan. c18871@pref.gifu.lg.jp
Abstract:A method for determination of 16 non-steroidal anti-inflammatory drugs (NSAIDs) in human plasma samples without time-consuming sample pre-treatments was developed. The system consisted of two pumps for mobile phase delivery, a six-port switching valve, a pre-column (Oasis HLB Cartridge Column), and a reversed phase analytical column (COSMOSIL 3C18-MS-II). The analytes were trapped on the precolumn and subsequently separated on the analytical column. The present method allowed on-line sample clean-up and enrichment, leading to improved sensitivity without any tedious sample preparation. The recoveries of NSAIDs from human plasma by column-switching were greater than 72.6%. The total analysis time for a single analytical run was approximately 11 min. The detection limits of NSAIDs were 0.0025 to 0.2 microg/mL using the selected ion monitoring mode.
Keywords:Column‐switching  Human plasma  LC–MS  Non‐steroidal anti‐inflammatory drugs
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏