首页 | 本学科首页   官方微博 | 高级检索  
     检索      


An ultra-stable referenced interrogation system in the deep ultraviolet for a mercury optical lattice clock
Authors:S T Dawkins  R Chicireanu  M Petersen  J Millo  D V Magalh?es  C Mandache  Y Le?Coq  S Bize
Institution:1. LNE-SYRTE, Observatoire de Paris, CNRS, UPMC, 75014, Paris, France
2. Escola de Engenharia de S?o Carlos, USP, S?o Carlos, SP, Brazil
3. Institut de Physique Nucléaire, Atomique et de Spectroscopie, Université de Liège, Liege, Belgium
Abstract:We have developed an ultra-stable source in the deep ultraviolet, suitable to fulfil the interrogation requirements of a future fully-operational lattice clock based on neutral mercury. At the core of the system is a Fabry–Pérot cavity which is highly impervious to temperature and vibrational perturbations. The mirror substrate is made of fused silica in order to exploit the comparatively low thermal noise limits associated with this material. By stabilizing the frequency of a 1062.6 nm Yb-doped fiber laser to the cavity, and including an additional link to LNE-SYRTE’s fountain primary frequency standards via an optical frequency comb, we produce a signal which is both stable at the 10?15 level in fractional terms and referenced to primary frequency standards. The signal is subsequently amplified and frequency-doubled twice to produce several milliwatts of interrogation signal at 265.6 nm in the deep ultraviolet.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏