Multidetector device for the detection of coincidences of charged particles and γ rays |
| |
Authors: | M. F. Kudoyarov V. V. Lobanov A. A. Pasternak S. I. Lashaev |
| |
Affiliation: | (1) A. F. Ioffe Physicotechnical Institute, Russian Academy of Sciences, 194021 St. Petersburg, Russia;(2) V. G. Khlopin Radium Institute, Russian Academy of Sciences, 194021 St. Petersburg, Russia |
| |
Abstract: | A 4π position-sensitive, axisymmetrical assembly of Si-Au charged-particle detectors is proposed, implemented, and tested on a beam of heavy ions; the dimensions and structure of the device are conducive to the organization of coincidences of charged reaction products with discrete γ rays emitted by the daughter nucleus and registered by a system of ultrapure Ge detectors. First results are obtained from an investigation of the reaction 58Ni(16O,α2pγ)68Ge at E 0=74.5 MeV. Zh. Tekh. Fiz. 68, 139–142 (April 1998) |
| |