首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Spectroscopic trace-gas sensor with rapidly scanned wavelengths of a pulsed quantum cascade laser for in situ NO monitoring of industrial exhaust systems
Authors:G Wysocki  A A Kosterev  F K Tittel
Institution:(1) Department of Electrical and Computer Engineering, Rice University, 6100 Main Street, Houston, TX 77251, USA
Abstract:Development of a pulsed quantum cascade laser (QCL)-based spectroscopic trace-gas sensor for sub-part-per-million detection of nitric oxide (NO) and capable of monitoring other molecular species such as CO2, H2O, and NH3 in industrial combustion exhaust systems is reported. Rapid frequency modulation is applied to the QCL to minimize the influence of fluctuating non-selective absorption. A novel method utilizes only a few laser pulses within a single wavelength scan to probe an absorption spectrum at precisely selected optical frequencies. A high-temperature gas cell was used for laboratory evaluation of the NO sensor performance. A noise-equivalent sensitivity (1sgr) of sim 100 ppb × m/ $$\sqrt{Hz}$$ at room temperature and sim 200 ppb × m/ $$\sqrt{Hz}$$ at 630 K was achieved by measuring the NO R(6.5) absorption doublet at 1900.075 cm–1.
Keywords:42  62  Fi  07  07  Df  42  55  Px
本文献已被 SpringerLink 等数据库收录!