摘    要:溶液中Al3+易水解,对游离酸的测定存在严重干扰。本文以NaF溶液掩蔽Al3+,用自动电位滴定仪测定含Al3+溶液中的游离酸含量,通过溶液化学分析论证了NaF溶液掩蔽Al3+的可行性。NaF掩蔽-自动电位滴定法测定含Al3+溶液中游离酸含量的精密度实验RSD小于2.0%,方法的加标回收率在98.00%~103.00%之间,与手动滴定法对比可靠性检验结果t=0.25;以上结果表明该方法具有准确度高、重复性好的优点。

关 键 词:电位滴定仪;游离酸;Al3+;NaF
收稿时间:2021-11-25
修稿时间:2021-12-19

Interference of Al3+ on the determination of free acid by potentiometric titrator and its elimination
Li Zishang,Zhang Zhiyong,Peng Xiaoyan,Yang Lin and Chen Shu. Interference of Al3+ on the determination of free acid by potentiometric titrator and its elimination[J]. Chinese Journal of Inorganic Analytical Chemistry, 2022, 12(5): 105-110
Authors:Li Zishang  Zhang Zhiyong  Peng Xiaoyan  Yang Lin  Chen Shu
Affiliation:Changsha Research Institute of Mining and Metallurgy Co Ltd,Changsha Hunan,Changsha Research Institute of Mining and Metallurgy Co Ltd,Changsha Hunan,Changsha Research Institute of Mining and Metallurgy Co Ltd,Changsha Hunan,Changsha Research Institute of Mining and Metallurgy Co Ltd,Changsha Hunan,Changsha Research Institute of Mining and Metallurgy Co Ltd,Changsha Hunan
Abstract:Interference of Al3+ on the determination of free acid by potentiometric titrator and its elimination Al3+ in solution is easy to hydrolyze, which seriously interferes with the determination of free acid. In this paper, NaF solution is used to mask Al3+, and the content of free acid in Al3+ containing solution is determined by automatic potentiometric titrator. The feasibility of masking Al3+ by NaF solution is demonstrated through solution chemical analysis. The precision of NaF masking automatic potentiometric titration for the determination of free acid content in Al3+ containing solution is less than 2.0%, the recovery of standard addition is 98.00% ~ 103.00%,and compared with manual titration, the reliability test result is t = 0.25. The results above show that the method has the advantages of high accuracy and good repeatability.
Keywords:potentiometric titrator   residual acid   Al3+   NaF
点击此处可从《中国无机分析化学》浏览原始摘要信息
点击此处可从《中国无机分析化学》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号