Field integral measurement of a six period undulator in a pulsed wire set up
Authors:Sumit Tripathi  Mona Gehlot  G Mishra  Sanjay Chouksey
Institution:
  • a School of Physics, DAVV, Indore, 452001, India
  • b RRCAT, Indore, 452001, India
  • c Department of Applied Physics, RGPV, Bhopal, MP, India
  • Abstract:A pulsed wire method is described for undulator field measurement. The results of the second field integral are compared with Hall probe results. The pulsed wire data are taken at different locations of the sensor along the length of the wire and with different gap of the undulator. A planar undulator with six periods is used in the pulsed wire set up. The total length of the undulator is 30 cm. The pulsed wire result shows good agreement with the Hall probe data.
    Keywords:
    本文献已被 ScienceDirect 等数据库收录!