首页 | 本学科首页   官方微博 | 高级检索  
     


Preconcentration speciation method for mercury compounds in water samples using solid phase extraction followed by reversed phase high performance liquid chromatography
Authors:Sánchez D M  Martín R  Morante R  Marín J  Munuera M L
Affiliation:Analytical Chemistry Unit, Chemistry Area (CIEMAT), Av. Complutense, 22, E-28040, Madrid, Spain.
Abstract:A simple and rapid method for in situ preconcentration of inorganic and organic mercury compounds in water samples, based on solid phase extraction using dithizone immobilised on a reversed-phase C18 cartridge, has been developed. The adsorbed complexes were stable on the cartridge for at least 2 weeks. The speciation analysis of methylmercury (MeHg), phenylmercury (PhHg) and inorganic mercury (Hg (II)) were done by reversed-phase high performance liquid chromatography. The calibration graphs of MeHg, PhHg and Hg (II) were linear (r>0.999) from the detection limits (0.58, 0.66 and 0.54 ng) to 38, 25 and 26 ng of Hg, respectively. The average recoveries of MeHg, PhHg and Hg (II) from spiked samples (0.3-48.0 mug l(-1) Hg) were 98+/-3, 99+/-1 and 100+/-7%, respectively. By applying SPE procedure a 200-fold concentration of the sample was obtained.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号