Determination of low concentrations of the flotation reagent ethyl xanthate by sampled DC polarography and flow injection with amperometric detection
Authors:Hidalgo P  Gutz I G
Institution:Instituto de Quimica, Universidade de S?o Paulo, Av. Prof. Lineu Prestes, 748-05508-900, S?o Paulo, SP, Brazil.
Abstract:A polarographic DC(tast) method with the static mercury drop electrode, SMDE, was developed for determination of the flotation collector ethyl xanthate (EtX) in the concentration range from 1x10(-5) to 8x10(-5) M. The potentiality of the method was demonstrated by evaluating the capacity of powdered galena ore (PbS) to adsorb EtX in a titration-like procedure. Sulfide could be determined simultaneously with EtX because in NaOH electrolyte their anodic waves are well separated (E(1/2) congruent with-0.72 and -0.42 V versus Ag/AgCl, respectively). In addition, a new FIA method was developed by adapting a simple device to the tip of the glass capillary of a mercury electrode and doing amperometric detection at a fixed potential of -0.1 V, always in the DC(tast) mode. No oxygen removal was required. Reproducible results were obtained at a frequency of 72 injections per h, with automatic renewal of the SMDE every second. The calibration curve for freshly prepared EtX standards rendered a straight line from 5x10(-6) to 8x10(-5) M with correlation coefficient of 0.997, suitable for real applications in flotation processes and its effluents.
Keywords:
本文献已被 PubMed 等数据库收录!