2,4,6-tri(3,5-Dimethylpyrazoyl)-1,3,5-triazine modified carbon paste electrode for trace Cobalt(II) determination by differential pulse anodic stripping voltammetry
Authors:Lu X  Wang Z  Geng Z  Kang J  Gao J
Institution:Institute of Chemistry, Northwest Normal University, Lanzhou, 730070, People's Republic of China.
Abstract:A differential pulse anodic stripping voltammetry was developed for the sensitive and selective determination of Co(II) at 2,4,6-tri(3,5-dimethylpyrazoyl)-1,3,5-triazine modified carbon paste electrode in 0.1 mol l(-1) NH(4)Cl solution (pH 4.95). The oxidation peak of Co(II) was observed at 0.03 V(vs. Ag/AgCl) by scanning the potential in a positive direction. The analysis procedure consisted of an open circuit accumulation step in stirred sample solution. This was followed by medium exchange to a clean solution and subsequently an anodic potential scan was effect to obtain the voltammetric peak. The current was proportional to the concentration of the Co(II) ion in a range of 1x10(-8)-1x10(-6) mol l(-1) for 3 min accumulation and in the range of 1x10(-9)-1x10(-8) mol l(-1) for 5 min accumulation; most of metal ions do not interfere with the determination. The developed method was applied to Co(II) determination in potable water.
Keywords:
本文献已被 PubMed 等数据库收录!